Regency 4734 Manual de instalación Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
Regency
®
Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
50
EXAMPLE 1: You could write a program that would cause an X-10 module to turn on an air
conditioner if one signal from the Model 4150 Auxiliary Control Module indicated that the
high temperature trip point had been exceeded (Condition A), another 4150 signal indicated
that the high humidity trip point had been exceeded (Condition B), or if both signals had been
received.
EXAMPLE 2: The system could be programmed to activate a relay on the Model 4180 Status
Display Module that would turn on an LED if Area #1 and Area #2 were both armed or both
disarmed (A = B).
Table 17: Logical Operators
Operator “ON” Output Is Generated When...
A AND B
Both Condition A and Condition B are in effect (for example, Area #1 is armed
and Area #2 is armed).
A OR B Either A or B or both is in effect.
A XOR B Either A or B is in effect, but not both.
NOT (A) The specified condition is not in effect.
A = B A and B are in the same state (in effect or not in effect).
EQZ (A) When A is zero (uses less memory than (A = 0)).
A > B If A is greater than B.
A < B If A is less than B.
Table 18: Arithmetic Operators
Operator Numerical Output* Generated is the Result of: Operator
A + B A + B A + B
A - B A - B A - B
A * B A * B A * B
DWN(A)
(Down Count) Value - 1 if value is greater than 0
(useful for timers).
DWN(A)
BIN(A)
Conversion of number from BCD (binary coded decimal) to binary.
Use to convert TSEC, TMIN, THR, MONTH, MDAY to binary before
comparison.)
BIN(A)
BCD(A) Conversion of binary number to BCD. BCD(A)
BIT(A) Conversion of number (0-7) to bit in byte. BIT(A)
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 69 70

Comentarios a estos manuales

Sin comentarios