Regency
®
Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
21
KEY BEEPS SPK:NO
If the installation includes a touchpad without a PZT beeper, you can use this option to send
the beeps from the touchpad to the internal speakers; however, they will sound at all internal
speakers.
E/E BEEP PZT:YES
Select this option if you wish to have the entry/exit tones sounded on the PZT beeper. (These
tones are always audible on the internal speakers.)
SWINGER BYPS:YES
When this option is selected, the system will automatically bypass any zone that generates four
alarms within a specified time period (programmed in TIMERS, Menu 13).
DELAYED BYPASS:YES
When this option is selected, the system will not report bypasses to the central station, until the
panel is armed.
AUT UNBYPASS:NO
This option will automatically unbypass the bypassed zones when the panel is disarmed, to
allow trouble conditions to be reported.
NOTE Since force arming may automatically cause zones to be bypassed, the AUTO UNBYPASS
option should be selected if the FORCE ARM option is enabled.
BYPASS CODE:NO
Selecting this option makes it impossible to bypass or unbypass a zone without first entering an
access code, even if the panel is disarmed.
REP BYPS ID:NO
When this option is selected, the user ID will be reported when anyone bypasses a zone. This
will only occur if the option BYPASS CODE has been selected. (Currently, the Model 9000
does not support this feature.)
ACCESS WINDW:NO
If this option is selected, all access codes are restricted to the time windows that have been
assigned to them (PROFILES, Menu 2). Selecting NO disables all time restrictions.
If you will be using access windows, see Section 5.2 of this manual. The access windows
restrict all functions that require an access code to certain times and days.
CHIME PZT:NO
When this option is selected, the chime tone will be heard at all touchpads assigned to the same
area as the chime zone. (If this option is not selected, the chime will be heard only at the speak-
ers.)
MAX SKEY ID:1 (Maximum Supervised Touchpad ID)
For this option, enter the highest touchpad ID number that will be supervised. Touchpads with
higher numbers may be used, but they will not display area entry/exit or LED information. You
must give your supervised touchpads ID numbers in sequential order, starting at 1; see the
Model 4720 Installation Manual (P/N 150476).
NOTE 1. Touchpads must be supervised to be fully functional.