Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
35
2. Multiply the per day number of seconds that the clock gains or loses by 6.07 to get the
adjustment factor.
3. If the clock is fast (gains time), subtract the adjustment factor from the current value of
TIME CALB.
4. If the clock is slow (loses time), add the adjustment factor to TIME CALB.
5. If the resulting number is:
■ less than zero, add 256 to get the new value for TIME CALB.;
■ greater than 255, subtract 256 to get the new value for TIME CALB.
CENTURY:00
Enter the century ( 1 9 or 2 0).
SERVICE ON: 00/00
On this date, the “SERVICE” message (System Message #8) will appear. The message is
cleared by entering and exiting a program mode (such as Set Time).
5.15 Key Options (Menu 14)
STATION:#1
Select the touchpad for which you wish to program options.
NOTE Station #0 options are not used. Begin programming with Station #1.
LOCATION#1
Enter the location text for Touchpad #1. Touchpad locations are used to annunciate panic key
alarms. The procedure for entering text is explained in Section 4.5 of this manual.
ARS#1:_ _ ___
Select the areas to be accessed by Touchpad #1.
NOTE When a panic key is pressed on a touchpad, all areas controlled by that touchpad go into
alarm.
INTERCOM#1:NO
This option enables the intercom function for Touchpad #1
NOTE Do NOT select DOOR on an intercom station, as this would disable the
TEL
key.
DOOR#1:NO
When this option is selected, door access is gained by entering a secret code on Touchpad #1.
NOTE On some touchpad models, DOOR and INTERCOM are not available together. It is possible to
select NO for both options.
HIGH SEC#1:NO
When this option is selected, the High Security Code must be entered in addition to the secret
code to gain door access.
DOOR ONLY#1:NO
When this option is selected, Touchpad #0 can be used only for door access, not for other func-
tions such as arming and disarming.