EXP ZONES#2:0
Enter the number of zones used on Zone Expander #2.
RESD CODE#2:0223
If Zone Expander #2 is an RF zone expander, enter its residence code. Skip this step if NOT
using an RF zone expander.
ARM MENU:NO
Causes the Interactive Arm Menu, normally used in split arm systems, to be active in all sys-
tems when a code is entered.
INST INTR:NO
When this option is selected, all delayed zones become instant zones whenever any intrusion
alarm occurs.
FORCE ARM:NO
This option causes any zones that are not ready to be bypassed (shunted) when the system is
armed. Upon arming, the 4734 will generate a “CF” (Forced Closing) Report.
NOTE Since Force Arming may automatically cause zones to be bypassed, the AUT UNBYPASS
option should be selected if the FORCE ARM option is enabled.
INTR INTRU:NO
When this option is selected, all interior zones will automatically be enabled when there is an
intrusion alarm.
INTR FLWRS:NO (Interior followers)
Selecting this option causes interior zone annunciations and reports to be delayed when an
entry zone is violated.
INTR LOCK:NO
This option disables the INT and DLY keys whenever the system is armed (after the exit
delay). This prevents anyone from disabling the interior zones while the system is armed.
AUT INTR OFF:NO
When selected, this option will automatically disable the interior zones when the system is dis-
armed.
AUT INTR ON:NO
When selected, this option will automatically disable the interior zones when the system is dis-
armed.
EXIT BEEPS:NO
This option causes an audible warning tone to be sounded during the exit delay.
SIL NGHT TRB:NO
When this option is selected, audible trouble tones will not be sounded while the panel is
armed.