Regency
®
Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
15
Figure 4: 7 TEST Menu Structure
Section 5: Programming Options Description
This section explains the options that can be programmed for the 4734. The options are listed
here are as they appear on the touchpad display when the built-in programmer is used. The
menu structure for the Model 5540 Downloading Software is slightly different. The selections
shown below are the factory-programmed default values.
NOTE This section shows ALL of the available options. However, some options will determine
whether or not another option is available.
EXAMPLE: If you selected NO for the AUTO TEST option, the DAILY TEST, TEST
DAY, and TEST TIME options will not function.
Before you begin programming, read through the options, then write down the selections you
plan to make in the programming record (P/N 150675). The procedure for using the built-in
programmer is explained in Section 4 of this manual. Instructions for using the Model 5540
Downloading Software can be found in Section 6 of this manual.
NOTE 1. After installing the 4734, you must reprogram all the options, even if the options had been
programmed previously. This is because the 4720 EEPROM, on which the options were origi-
nally programmed, is no longer used.
2. When the 4734 is installed, options can be programmed using the 4734’s built-in program-
mer (accessed through any 4000 series touchpad) or the Model 5540 Downloading Software.
The Model 5520 Desk Top Programmer cannot be used with the Model 4734.
5.1 Time Windows (Menu 0)
The 4734 provides 32 available time windows (time periods), each specified by days of the
week and a starting and ending time. Each access code can be programmed to be used during
any combination of the 32 time windows (PROFILES, Menu 2).
Opening and closing can be enabled by a programmed combination of the 32 time windows.
Each time window can also be enabled on holidays. Up to 16 calendar days can be designated
as holidays (HOLIDAYS, Menu 3).
For auto-arming, there is a programmable delay period during which the user may extend the
delay or cancel the auto-arm. During the delay, the time remaining will be displayed at the
touchpads along with an audible warning. This delay is programmed in TIMERS (Menu 13).
These features replace the NORMAL/SPECIAL and CLOSED DAYS option previously used
with the 4720. Time windows can be programmed by the end-user to provide optimum system
flexibility.
NUMBER:#0
Select the time window to program.
8457G31A.DSF