Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
18
WIN GRP#0:32
Select the time window group (programmed in WINDOW GROUPS, Menu 11) during which
this user profile may be used. To make it possible to use a profile all the time, select ALWAYS
(3 2). To make it impossible to use a profile at any time select NEVER (3 3).
NOTE These options apply to all users using this profile.
EXAMPLE: Suppose you have programmed Time Window #1 for 8:00 AM to 5:00 PM
Monday through Friday, and you have programmed Time Window #2 for 10:00 AM to
5:00 PM on Saturdays (TIME WINDOWS, Menu 0). Then, suppose you have assigned
Windows #1 and #2 to Window Group #4 (WINDOW GROUPS, Menu 11).
If you want the code to be able to gain access and/or use a touchpad during the times from
8:00 AM to 5:00 PM on weekdays, and from 10:00 AM to 5:00 PM on Saturdays, then
select 4 for the WIN GRP option. Any group may be assigned to any profile and to more
than one profile. A profile may be assigned to only one window group.
5.4 Holidays (Menu 3)
Up to 16 calendar days can be designated as holidays. Holidays can be programmed by the
end-user.
DATE#1:01/01
Key in the date (month and day) you want to assign as the first holiday. Use leading zeros
before single-digit data.
DATE#2:01/01
Key in the month and day you want to assign as the second holiday.
5.5 DST Dates (Menu 4)
The daylight savings adjustment dates can be programmed by the end-user. Adjustments occur
at 2:00 AM on the specified date.
FWD DATE:00/00
Key in the month and day when you want the time to be set one hour forward automatically,
for the spring (forward) daylight-savings time adjustment.
BACK DATE:00/00
Key in the month and day when you want the time automatically to be set one hour back, for
the fall (back) daylight-savings time adjustment.
NOTE To disable holidays or DST dates, enter
0 0 / 0 0
for the date.
5.6 System (Menu 5)
DEF/MODE:FORCE (Default Mode)
This option is used to determine what the system will do when it times out of Program Mode or
when power is restored to the panel. This would occur after power has been lost, then restored
to the panel, if no one is present to control the system. Key in the number shown beside the
desired selection in Table 6.
EXAMPLE: All power is lost at the panel (AC and DC). When the power is restored, the
panel will enter the SET TIME Mode. If no action is taken by the user after four minutes,
the panel will enter DEFAULT Mode.
Vista de pagina 25