Table 15: Status and Port Addresses
Names Address.Point Operations Functions
AARMED[1-8]
AACAREA
ACHIME[1-8]
ACODE2[1-8]
@$B0-7.0
@$564.0-7
@$B0-7.3
@$B0-7.4
GET1
GET1
GET1
GET1
Area armed
Last group of area granted door access
Area chime activated
Area Code2 activated
AENTRY[1-8]
AEXIT[1-8]
AINST[1-8]
ALMAREA 0.-7
@$B8-F.1
@$B8-F.0
@$B0-7.2
@$79.0-7
GET1
GET1
GET1
GET1,GET8
Area entry activated
Area exit activated
Area instant activated
Area in alarm
AREADY[1-8]
ABYPASS[1-8]
ATROUBLE[1-8]
AUDALM
@$B0-7.1
@$B0-7.5
@$B0-7.6
@$27.7
GET1
GET1
GET1
GET1
Area zones ready
Area zones bypassed
Area zone trouble
Audible alarm
AUDAREA.0-.7
AUXALM
AUXRLY.0-.7
AZONES[1-10].0-.7
@$78.0-7
@$26.1
@$6D.0-7
@$372-$37B.0-7
GET1,GET8
GET1
GET1,GET8
GET1,GET8
Area audible alarm
Aux. alarm activated
4150 relay status
Armed zones
BYPASS
DACT
DOOR80.0-.7
DOOROPEN[0-15]
@$25.5
@$68.2
@$18.0-7
@$3E1-$3F0.2
GET1
GET1
GET1,GET8
GET1
Global zones bypassed
Dialer active
Toggle with 1-8 door
Touchpad door open
DOORRLY[0-15]
DOORSUPR[0-15]
DOORBYPS[0-15]
DURESS
@$3E1-$3F0.7
@$3E1-$3F0.1
@$56D-$57C.0
@$26.6
GET1,PUT1
GET1
GET1,PUT1
GET1
4433/4420 touchpad relay status
Touchpad door trouble
Touchpad door bypass
Duress alarm
EMER
EXEC
EXTBELL
FIRE
@$2A.1
@$3F.0
@$29.3
@$28.0
GET1
GET1
GET1
GET1
Emergency alarm
IF/THEN control bit
External bell active
Fire alarm
HLDAY
HZNC[1-10].0-.7
HDEBO[1-10].0-.7
ICALL
@$2A.0
@$2BC-$2C5.0-7
@$2A4-$2AD.0-7
@$564
GET1
GET1,GET8
GET1,GET8
GET8
Holiday
Zone high threshold trip
Debounced high threshold trip
Station # for intercom call
ICOM
INTBELL
INTRU
IRDY
IZONES[1-10].0-.7
@$6C.0
@$29.2
@$28.2
@$24.0
@$37C-$385.0-7
GET1
GET1
GET1
GET1
GET1,GET8
Intercom active
Internal bell active
Intrusion alarm
Zones all ready
Interior bypassed zones
KEYSUPR[0-15]
LISTEN
LOWBAT[1-10].0-.7
LZNC[1-10].0-.7
@$3E1-$3F0.0
@$68.3
@$368-$371.0-7
@$2B2-$2BB.0-7
GET1
GET1
GET1,GET8
GET1,GET8
Touchpad supervision
Listen in active
Zones low battery
Zones low threshold trip
LDEBO[1-10].0-.7
MDAY
MONTH
P1SEC
@$29A-$2A3.0-7
@$7
@$6
@$5.4
GET1,GET8
GET8
GET8
GET1
Debounced low threshold trip
Day of month (1-31)
Month (1-12)
One-second pulse
P500MS
PAPOUT
PASS1
PASS10
@$5.3
@$69.0
@$74.5
@$74.6
GET1
GET1
GET1
GET1
Half-second pulse
Printer out of paper
True for one pass of I/O prog. each sec.
True for one pass of I/O prog. each 10 sec.
PASS60
PHONE
REPORT
RLY[1]
@$74.7
@$6C.1
@$27.1
@$8E.0-7
GET1
GET1
GET1
GET1/PUT1,8
True for one pass of I/O prog. each min.
4140 Phone Mode
Reporting
4180 outputs Unit #1, P2
RLY[2]
RLY[3]
RLY[4]
SCR[1-8]
@$8F.0-7
@$90.0-7
@$91.0-7
@$408-$40F.0-7
GET1/PUT1,8
GET1/PUT1,8
GET1/PUT1,8
GET1/PUT1,8
4180 outputs Unit 1, P3
4180 outputs Unit 2, P2
4180 outputs Unit 2, P3
Scratch locations*
NOTE 1. Some addresses in this table are different from the 4724 addresses.
2. Scratch locations can be used as counters or as places to save temporary results in a program, if
needed.